skip to main content


Search for: All records

Creators/Authors contains: "Dawson, Robin M. A."

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. In time-correlated single-photon counting (TCSPC), photons that arrive during the detector and timing electronics dead times are missed, causing distortion of the detection time distribution. Conventional wisdom holds that TCSPC should be performed with detections in fewer than 5% of illumination cycles to avoid substantial distortion. This requires attenuation and leads to longer acquisition times if the incident flux is too high. Through the example of ranging with a single-photon lidar system, this work demonstrates that accurately modeling the sequence of detection times as a Markov chain allows for measurements at much higher incident flux without attenuation. Our probabilistic model is validated by the close match between the limiting distribution of the Markov chain and both simulated and experimental data, so long as issues of calibration and afterpulsing are minimal. We propose an algorithm that corrects for the distortion in detection histograms caused by dead times without assumptions on the form of the transient light intensity. Our histogram correction yields substantially improved depth imaging performance, and modest additional improvement is achieved with a parametric model assuming a single depth per pixel. We show results for depth and flux estimation with up to 5 photoelectrons per illumination cycle on average, facilitating an increase in time efficiency of more than two orders of magnitude. The use of identical TCSPC equipment in other fields suggests that our modeling and histogram correction could likewise enable high-flux acquisitions in fluorescence lifetime microscopy or quantum optics applications.

     
    more » « less
  2. Single-photon lidar (SPL) is a promising technology for depth measurement at long range or from weak reflectors because of the sensitivity to extremely low light levels. However, constraints on the timing resolution of existing arrays of single-photon avalanche diode (SPAD) detectors limit the precision of resulting depth estimates. In this work, we describe an implementation of subtractively-dithered SPL that can recover high-resolution depth estimates despite the coarse resolution of the detector. Subtractively-dithered measurement is achieved by adding programmable delays into the photon timing circuitry that introduce relative time shifts between the illumination and detection that are shorter than the time bin duration. Careful modeling of the temporal instrument response function leads to an estimator that outperforms the sample mean and results in depth estimates with up to 13 times lower root mean-squared error than if dither were not used. The simple implementation and estimation suggest that globally dithered SPAD arrays could be used for high spatial- and temporal-resolution depth sensing.

     
    more » « less
  3. Abstract

    Non-line-of-sight (NLOS) imaging is a rapidly growing field seeking to form images of objects outside the field of view, with potential applications in autonomous navigation, reconnaissance, and even medical imaging. The critical challenge of NLOS imaging is that diffuse reflections scatter light in all directions, resulting in weak signals and a loss of directional information. To address this problem, we propose a method for seeing around corners that derives angular resolution from vertical edges and longitudinal resolution from the temporal response to a pulsed light source. We introduce an acquisition strategy, scene response model, and reconstruction algorithm that enable the formation of 2.5-dimensional representations—a plan view plus heights—and a 180field of view for large-scale scenes. Our experiments demonstrate accurate reconstructions of hidden rooms up to 3 meters in each dimension despite a small scan aperture (1.5-centimeter radius) and only 45 measurement locations.

     
    more » « less